Application |
universally applicable sensor with stainless steel sleeve for measuring in liquids and air
|
Measuring range |
−35…+100°C (+250°C, +400°C)
|
sensor |
Pt 100, Pt 1000 according to DIN EN 60751
|
Accuracy class |
A, B or 1/3 DIN B (at 0°C)
|
Circuit type |
|
Measuring current |
max. 1mA (Pt 100), max. ≤0.3mA (Pt 1000)
|
Protective tube ød |
ø2…ø6mm (Pt 100), ø2.5…ø6mm (Pt 1000) or depends on the connection cable used
|
Protective tube material |
|
Nominal length NL |
Standard lengths: 60mm, 150mm, or as specified
|
Process connection |
without (adjustable compression fittings available as accessories)
|
connecting cable |
Length: 2m (standard) with free, tinned ends in the possible insulations:
- PVC insulation (Tmax: 70°C or 100°C)
- Silicone/FEP insulation (Tmax: 200°C)
- PFA insulation (Tmax: 250°C)
- PFA insulation, shielded (Tmax: 250°C)
- Glass silk with metallic outer braid (Tmax. 400°C)
|
Insulation resistance |
≥100 MΩ at +20°C (100V DC)
|
Options |
- Anti-kink spring
- Plug according to specifications
- Ends with wire end ferrules
|