PAR-Sensor VDC

€900.15 * (€756.43 netto zzgl. MwSt.)

* Prices incl. VAT plus shipping costs

Delivery time 14 Workdays

Measuring range:

Measuring range limitation:

Output signal:

Data logger:

Cable glands:

additional cable [m]:

Power supply:

Certificats:

  • 10.03.03.03
  • Zolltarif-Nr.:
  • VRS-Nr.:
Normal 0 21 false false false... more
Product information "PAR-Sensor VDC"

The quantum sensor is used to measure the natural and artificial light radiation (Photosynthetic Active Radiation "PAR") relevant for the growth of plants. For the photosynthesis only the range of approx. 400 to 700 nanometers wavelength of the light radiation is important.

The photosynthetic photon flux density (PPFD) is detected by the quantum sensor in this spectral range. To compensate for all incident photons, the sensor sensitivity for the energy-rich, short-wave photons is smaller than for the energy-intensive, long-wave photons. This results in the typical PAR characteristic.

The quantum sensor is equipped with a detector approximating this characteristic curve.

Our quantum sensors are optimized for use on data loggers and control systems.

The basic design of the PAR quantum sensor:
• Measuring range of e.g. 0 and 2000 μmol / m²
• linear output signal from 0 to 10 mV

In addition, we offer the following options:
• integrated measuring amplifiers (for example, 0..1 V, 0..10 mA for 0..4000 μmol / m²s or similar, at 12 VDC)
• 3-point adjustment plates with canibelle for leveling
• Counter plates for easy mounting on narrow or round surfaces
• Underwater versions
• very fast sensors

Sensor Type: PAR Quantum Sensor
Norm: VDI 3786 Part 5 Radiation Measurement
Norm - WMO: WMO-No,8 7th Edition Part I Chapter 7 Measurement of radiation
Application: Agriculture, climate measurements, industry, Research
Manufacturer: deka Sensor + Technologie
Measurement methods: Si Photodiode
Spectral range [nm]: 400...700
max. Spectral sensitivity [nm]: 600
Measuring range [mol / m2s]: 10.000 , 1000 , 2000
Measurement Accuracy: ± 5 %
azimuth effect: 2%
response time [t95 s]: < 5 ms
Long-term stability: 2 % / a
Linearity: < 1%
abs. Error: < 3%
Medium: Air, Water
cosine correction: f2 < 3%
Measuring head separate from the transmitter :: Sensorseitig Steckverbinder 713
Connection {Plug: Standard cable special PVC length 1.4m
Mobile data capture radiation:: handheld device, Multichannel datalogger, Single channel data logger
Output signal : 0 ... 10 mA, 0 ... 20 mA, 0...1V DC, 0...5VDC, 0...10mV, 0...10VDC, 0...50mV, 0...100mV, 4 ... 20 mA
Output signal limitation: < 3 V, < 6 V, < 12 VDC, < 21 mA, unlimited
Amplifier: Three wire transmitter
voltage supply: 5 VDC, 10 ... 30 VDC, 10...24VDC, 12VDC
Degree of protection: IP65
Operating temperature [° C]: -30°C...+60°C